Desulfurization system
The stored limestone slurry is sprayed counter-currently against the power plant boiler flue gas, absorbing SO2 from the flue gas. The SO2 reacts with oxygen and limestone forming gypsum. Krebs cyclones concentrate the gypsum slurry from about 15% solids by weight to 45% solids by weight ahead of a vacuum belt filter.